Oil Gas Fired Thermic Fluid Heater

“Thermotech Systems Limited” a name in Process Heating Technology, which delivers Thermic Fluid Heaters with distinct technology that suits all process & gives optimum efficiency & automation. The company is formed in 1988 & is achieving excellence in product & market thereafter for continuously more than 2 decades & is still marching ahead with its product adherence & acceptance in industry across World.


“Thermotech” : Thermic Fluid Heater’s are available in Horizontal & Vertical Models where in thermic fluid can be heated up to normal 340 oC at near atmospheric pressure with efficiency as high as 92% on GCV of Oil and Gas fuel. 


Thermic Fluid Heater Capacity = 1 Lac Kcal/hr to 120 Lac Kcal/hr

Maximum Temperature
= 370 Deg. C

Applications:

Chemical, Textile, Technical Textile, MDF and Particle Board, Plywood and Laminates, Oil & Gas, Packaging, Rubber, Pharmaceuticals, Food Processing, Metal etc.

Fuel to Handle : Furnace Oil, LDO, Diesel, N. Gas, LPG, Hydrogen, etc..

Quality Assurance : ISO 9001 : 2008 since more than 7 years.

Oil Gas Fired Thermic Fluid Heater

Oil Gas Fired Thermic Fluid Heater
  • Oil Gas Fired Thermic Fluid Heater
  • Oil Gas Fired Thermic Fluid Heater
Ask For Price
Product Price :Get Latest Price

Product Details:

Tank Capacity0.1 to 6 Million kcal/hr
Efficiencyas high as 87%
BrandThermotech
ServiceOEM
MaterialSS
ApplicationChemical,Textile,Technical Textile,MDF and Particle Board,Plywood and Laminates,Oil and Gas

Being an eminent Organization, we hold expertise in offering a wide range of Oil Gas Fired Thermic Fluid Heater. These are manufactured by us using quality materials, which are procured from reliable vendors of the market. Owing to their superior quality and reliable performance, these heaters are widely demanded across various Industries. To cater the variegated requirements of the customers, these are offered by us in various technical specifications.

Features:

  • Rigid construction
  • Easy installation
  • Minimum maintenance
Request
Callback
Yes! I am Interested

Gas Oil Fired Thermic Heater

Gas Oil Fired Thermic Heater
  • Gas Oil Fired Thermic Heater
  • Gas Oil Fired Thermic Heater
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Unit
MaterialSS, MS
Efficiency93%
Brand Thermotech
Service OEM
Application Industrial
Surface Galvanized

Thermotech''s, this new “HT” series of Gas Oil Fired Thermic Heater – Horizontal model is improved version, which have demonstrated their good design & to which new Technologies & Materials are added to improve efficiency up to 93%, energy saving, simplify the maintenance, low smoke emission & able to integrate with PLC & SCADA system with ease.

The Stack Heat from Exhaust flue gases of Main Heat Ex-changer are recovered by means of Combustion Air Pre Heater (CAPH) & fresh combustion air is preheated before going to burner, which improves combustion efficiency, reduces stack temperature, reduce fuel consumption & save environment.

All the Horizontal type Thermic Fluid Heaters are equipped with a reputed make Mono-block or Dual block Burner with on-off / 2 stage / progressive modulation - suitable for fuel specified by client & selected as per the capacity of Thermic fluid heater. The Heating & Pumping system for Heavy Fuel Oil and Gas Train for Natural Gas / LPG are supplied with equipments as an optional equipment for efficient and safe operation of Burner.
Request
Callback
Yes! I am Interested

Gas Oil Fired Burner Thermic Heater

Gas Oil Fired Burner Thermic Heater
  • Gas Oil Fired Burner Thermic Heater
  • Gas Oil Fired Burner Thermic Heater
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

MaterialSS, MS
Brand Thermotech
Service OEM
Application Industrial
Surface Galvanized
Efficiency92%

Gas Oil Fired Burner Thermic Heaters are available in Horizontal & Vertical Models where in thermic fluid can be heated up to normal 340 degree Celcius at near atmospheric pressure with efficiency as high as 92% on GCV of Oil and Gas fuel. The Main Heat Exchanger is designed with an integrated combustion chamber made out of High Heat Resistant Steel Tubes : BS 3059 P-1 or Seamless Pipes : SA106 Gr.B S40 of adequate size, explicitly designed with twin concentric multi start helical coil. The Coil is inserted into M.S. Shell with structures supports to place complete assembly leveled.

The system is 3 pass on flue gas side, which ensures optimum heat transfer with counter current flow principle. The combustion chamber is designed to maintain safe distance between coil tube surface and burner flame, which ensures optimum heat transfer, long thermic fluid life due to lesser film temperature & safety of helical coil tube, which ultimately safeguards the complete heat exchanger.

The Combustion Fuels :

Fuels like : Kerosene / Diesel / Light Diesel Oil (LDO-LFO) / Furnace Oil (HFO) / Natural Gas / LPG / Pipeline N. Gas, etc. are combustible with same efficiency, which is thankful to our combustion experts who designs combustion parameters & Air to fuel ratio for best output.

Features:

  • Excellent performance
  • Low power consumption
  • Longer service life
Request
Callback
Yes! I am Interested

Oil Gas Fired Thermic Fluid Heater

Oil Gas Fired Thermic Fluid Heater
  • Oil Gas Fired Thermic Fluid Heater
  • Oil Gas Fired Thermic Fluid Heater
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

BrandThermotech
Usage/ApplicationIndustrial
MaterialCS
TypeHorizontal / Vertical
Heating SourceGas / Oil
Fuel TypeOIL / GAS
Firing ModeHorizontal / Vertical
ColorCladding
Maximum Temperature380
Heat OutputAS per requirement
Max Working Temp.340
Model Name/NumberTSH / TSV
ApplicationIndustrial

Thermotech” : Thermic Fluid Heater’s are available in Horizontal & Vertical Models where in thermic fluid can be heated up to normal 340 oC at near atmospheric pressure with efficiency as high as 92% on GCV of Oil and Gas fuel.

Thermic Fluid Heater Capacity = 0.1 MKcal/hr to 15 MKcal/hr

Maximum Temperature = 370 Deg. C

Application:

Chemical, Textile, Technical Textile, MDF and Particle Board, Plywood and Laminates, Oil & Gas, Packaging, Rubber, Pharmaceuticals, Food Processing, Metal, etc...

Fuel to Handle : Furnace Oil, LDO, Diesel, N. Gas, LPG, Hydrogen, etc..

Quality Assurance : ISO 9001 : 2008 since more than 7 years.

Thermic Heater - Gas Oil / Fired Burner

“THERMOTECH” : THERMIC FLUID HEATER’S are available in HORIZONTAL & VERTICAL MODELS where in thermic fluid can be heated up to normal 340 oC at near atmospheric pressure with efficiency as high as 92% on GCV of Oil and Gas fuel.

The Main Heat Exchanger is designed with an integrated combustion chamber made out of High Heat Resistant Steel Tubes : BS 3059 P-1 or Seamless Pipes : SA106 Gr.B S40 of adequate size, explicitly designed with twin concentric multi start helical coil. The Coil is inserted into M.S. Shell with structures supports to place complete assembly leveled.

The system is 3 pass on flue gas side, which ensures optimum heat transfer with counter current flow principle. The combustion chamber is designed to maintain safe distance between coil tube surface and burner flame, which ensures optimum heat transfer, long thermic fluid life due to lesser film temperature & safety of helical coil tube, which ultimately safeguards the complete heat exchanger.

HORIZONTAL UNIT WITH EXTERNAL AIR PRE HEATER

This new “HT” series of Thermic Fluid Heater – Horizontal model is improved version, which have demonstrated their good design & to which new Technologies & Materials are added to improve efficiency up to 93%, energy saving, simplify the maintenance, low smoke emission & able to integrate with PLC & SCADA system with ease.

The Stack Heat from Exhaust flue gases of Main Heat Exchanger are recovered by means of Combustion Air Pre Heater (CAPH) & fresh combustion air is preheated before going to burner, which improves combustion efficiency, reduces stack temperature, reduce fuel consumption & save environment.

The Combustion Fuels :

“THERMOTECH” : Thermic Fluid Heaters are designed for all commercial & special fuels available in market for combustion.

Fuels like : Kerosene / Diesel / Light Diesel Oil (LDO-LFO) / Furnace Oil (HFO) / Natural Gas / LPG / Pipeline N. Gas, etc. are combustible with same efficiency, which is thankful to our combustion experts who designs combustion parameters & Air to fuel ratio for best output.

Request
Callback


Additional Information:

  • Item Code: 00304
  • Production Capacity: 20 M Kcal/hr
  • Delivery Time: 1
  • Packaging Details: As per Client Specs.
Yes! I am Interested

Automatic Thermic Fluid Heater

Automatic Thermic Fluid Heater
  • Automatic Thermic Fluid Heater
  • Automatic Thermic Fluid Heater
  • Automatic Thermic Fluid Heater
  • Automatic Thermic Fluid Heater
  • Automatic Thermic Fluid Heater
  • Automatic Thermic Fluid Heater
  • Automatic Thermic Fluid Heater
Ask For Price
Product Price :Get Latest Price

Product Details:

Minimum Order Quantity1 Unit
Tank Capacity1m3

Salient Features of This Model Furnace is designed for multi fuel options, with major thrust on proper selection of combustion grate, furnace height, combustion volume, fuel feeding systems. To ensure efficient combustion & lesser heat loss. Coils are designed with optimum flow consideration to gain maximum heat from flue gases. Coils are tested at 3 stages before final dispatch as a part of Thermotech’s stringent quality control. ID Fan, FD Fan & booster fan (in any) are selected as per fuel’s perfect air-fuel ratio requirement, which ensures optimum air quantity for combustion & thus saves power consumption. Expansion Tank capacity is specifically selected after consulting total holdup of Thermic Oil. Deaeration Tank is specially designed considering flow & temperature requirement. Thermotech offers complete solution of Thermic Fluid heating system along with Pipeline, Pollution control equipments, fuel handling, etc on Turnkey basis. Auto Controls & Safety 1. Thermic Fluid Temperature control Digital temperature indicator-cum-controller cut of ID/FD fan of preset temperature and restart of preset temperature and restart of preset differential temperature to maintain system temperature. 2. Stack Temperature Control A blind temperature controller cut of ID/FD fan and sound alarm if stack temperature exceeds to preset temperature. 3. Low/NO Flow of Thermic Fluid Differential pressure switch connected across intel and outlet headers signals low flow alarm in case of low fluid pressure of Thermic fluid in coils. 4. Low Level of Thermic Fluid The visual level indicator and float actuated lever switch fitted in expansion tank signals alarm in case of low level thermic fluid in the system. 5. Thermic Fluid Pump Motor Trip In case of thermic fluid pump motor trip, electrical interlocks, cut off ID/FD fan. 6. Power Failure Diesel engine drive keeps thermic fluid moving in the system to prevent its degradation and overflow. 7. Excess Furnace Bed Temperature Digital temperature indicator-cum-controller senses furnace bed temperature and cut off ID/FD fan above set value(for FBC unit). Benefites : Multi-Fuel Option Low Power Consumption Energy Optimization Low Maintenance
Request
Callback
Yes! I am Interested

API 560 Fired Heaters

API 560 Fired Heaters
  • API 560 Fired Heaters
  • API 560 Fired Heaters
Ask For Price
Product Price :Get Latest Price

Product Details:

Minimum Order Quantity1 Unit
TypeVertical Heater
Heating SourceIndirect
Fuel TypeOil/Gas
Firing ModeUpward
Heater MaterialCS
MaterialCS
Heat Output20 M Kcal/hr
Temperature340
Size1

In Oil & Gas segment fired heaters are an essential requirement for heating Thermic Oil, process fluids Feed stock , charge heating , steam heating and for thermal cracking in the refinery segment of oil & gas sector, The design of these units depends on the application and the choice can be between ‘vertical cylindrical' or ‘box-type furnace' designs. These units are offered either for Offshore or for On shore installation.

The heaters are designed in accordance to API codes, are equipped with multi fuel firing capabilities and are engineered to operate at high efficiency. The design can incorporate air pre heat systems that make use of carbon steel, cast iron or glass tubes to achieve high efficiency.
Request
Callback


Additional Information:

  • Item Code: 1000
  • Production Capacity: 20 M Kcal/hr
  • Delivery Time: 1
  • Packaging Details: As per client...
Yes! I am Interested

Semi-Automatic Thermic Fluid Heater

Semi-Automatic Thermic Fluid Heater
  • Semi-Automatic Thermic Fluid Heater
  • Semi-Automatic Thermic Fluid Heater
Ask For Price
Product Price :Get Latest Price

Product Details:

Minimum Order Quantity1 Unit
Tank Capacity1m3

Salient Features of This Model Furnace is designed for multi fuel options, with major thrust on proper selection of combustion grate, furnace height, combustion volume, fuel feeding systems. To ensure efficient combustion & lesser heat loss. Coils are designed with optimum flow consideration to gain maximum heat from flue gases. Coils are tested at 3 stages before final dispatch as a part of Thermotech’s stringent quality control. ID Fan, FD Fan & booster fan (in any) are selected as per fuel’s perfect air-fuel ratio requirement, which ensures optimum air quantity for combustion & thus saves power consumption. Expansion Tank capacity is specifically selected after consulting total holdup of Thermic Oil. Deaeration Tank is specially designed considering flow & temperature requirement. Thermotech offers complete solution of Thermic Fluid heating system along with Pipeline, Pollution control equipments, fuel handling, etc on Turnkey basis. Auto Controls & Safety

1. Thermic Fluid Temperature control Digital temperature indicator-cum-controller cut of ID/FD fan of preset temperature and restart of preset temperature and restart of preset differential temperature to maintain system temperature.
2. Stack Temperature Control A blind temperature controller cut of ID/FD fan and sound alarm if stack temperature exceeds to preset temperature.
. Low/NO Flow of Thermic Fluid Differential pressure switch connected across intel and outlet headers signals low flow alarm in case of low fluid pressure of Thermic fluid in coils.
4. Low Level of Thermic Fluid The visual level indicator and float actuated lever switch fitted in expansion tank signals alarm in case of low level thermic fluid in the system.
5. Thermic Fluid Pump Motor Trip In case of thermic fluid pump motor trip, electrical interlocks, cut off ID/FD fan.
6. Power Failure Diesel engine drive keeps thermic fluid moving in the system to prevent its degradation and overflow.
7. Excess Furnace Bed Temperature Digital temperature indicator-cum-controller senses furnace bed temperature and cut off ID/FD fan above set value(for FBC unit).

Benefites : Multi-Fuel Option Low Power Consumption Energy Optimization Low Maintenance
Request
Callback
Yes! I am Interested

Petcoke Fired Thermic Fluid Heater

Petcoke Fired Thermic Fluid Heater
  • Petcoke Fired Thermic Fluid Heater
  • Petcoke Fired Thermic Fluid Heater
Ask For Price
Product Price :Get Latest Price

Product Details:

Minimum Order Quantity1 Unit
Tank Capacity1m3

Salient Features of This Model Furnace is designed for multi fuel options, with major thrust on proper selection of combustion grate, furnace height, combustion volume, fuel feeding systems. To ensure efficient combustion & lesser heat loss. Coils are designed with optimum flow consideration to gain maximum heat from flue gases. Coils are tested at 3 stages before final dispatch as a part of Thermotech’s stringent quality control. ID Fan, FD Fan & booster fan (in any) are selected as per fuel’s perfect air-fuel ratio requirement, which ensures optimum air quantity for combustion & thus saves power consumption. Expansion Tank capacity is specifically selected after consulting total holdup of Thermic Oil. Deaeration Tank is specially designed considering flow & temperature requirement. Thermotech offers complete solution of Thermic Fluid heating system along with Pipeline, Pollution control equipments, fuel handling, etc on Turnkey basis. Auto Controls & Safety 1. Thermic Fluid Temperature control Digital temperature indicator-cum-controller cut of ID/FD fan of preset temperature and restart of preset temperature and restart of preset differential temperature to maintain system temperature. 2. Stack Temperature Control A blind temperature controller cut of ID/FD fan and sound alarm if stack temperature exceeds to preset temperature. 3. Low/NO Flow of Thermic Fluid Differential pressure switch connected across intel and outlet headers signals low flow alarm in case of low fluid pressure of Thermic fluid in coils. 4. Low Level of Thermic Fluid The visual level indicator and float actuated lever switch fitted in expansion tank signals alarm in case of low level thermic fluid in the system. 5. Thermic Fluid Pump Motor Trip In case of thermic fluid pump motor trip, electrical interlocks, cut off ID/FD fan. 6. Power Failure Diesel engine drive keeps thermic fluid moving in the system to prevent its degradation and overflow. 7. Excess Furnace Bed Temperature Digital temperature indicator-cum-controller senses furnace bed temperature and cut off ID/FD fan above set value(for FBC unit). Benefites : Multi-Fuel Option Low Power Consumption Energy Optimization Low Maintenance
Request
Callback
Yes! I am Interested

Oil Fired Vertical Thermic Fluid Heater

Oil Fired Vertical Thermic Fluid Heater
  • Oil Fired Vertical Thermic Fluid Heater
  • Oil Fired Vertical Thermic Fluid Heater
Ask For Price
Product Price :Get Latest Price

Product Details:

Minimum Order Quantity1 Piece
Tank Capacity1m3

Backed by our well structured infrastructure unit, we are affianced in providing precision engineered Oil/Gas Fired Hot Water Generator. This generator is a safer and economical system which delivers hot water much faster than any other system. It''s most ideal usage includes hotels, hospitals, residential complex, laundry, dairy industries, etc., where continuous hot water supply is essentially required. The offered generator is efficiently manufactured using standard quality components and advanced machines in complete sync with defined industry standards. Additionally, the offered Oil/Gas Fired Hot Water Generator is stringently tested on certain parameters under the direction of our deft quality controllers. Features: Energy efficient Trouble free functioning Easy to operate Longer service life The WATERTHERM is a very compact fully automatic packaged hot water generator in ready to install condition and can be installed where ever space is available. It does not require any special room like boiler house. It falls outside the purview of Indian Boiler Regulations. WATERTHERM is a safer and economical system which delivers hot water much faster than any other conventional system. It''s most ideal usage includes HOTELS, HOSPITALS, RESIDENTIAL COMPLEX, LAUNDRY, DAIRY INDUSTRIES, etc. where continuous hot water supply is essentially required. WATERTHERM system is available in wide range of heat output from 0.1 Mkcals/hr. to 15 Mkcal/hr., A New Perception In Quality Thermotech Established Back In 1988, Is Today A Leading Industry In Process Heating Systems. The Great Impetus Lies In The Hard Work, No Quality Compromise, Implementing Latest Technologies And Above All Incredibly Environmental Compliance. A Large Network In India Provides Prompt And Assured Quality Service To Our Valued Clients Within No Time. Watertherm - A New Concept In Hot Water Boilers Heat Exchanger Of Hot Water Generator Are Fabricated Out Of Boiler Tube Bs 3059 Of Adequate Size, Accurately Designed With Concentric Multi Start - Three Flue Gas Passes To Ensure Optimum Heat Transfer With Low Flue Gas Exit Temperature Operates Watertherm At A Constant Efficiency Of 88 % (on Ncv @ Mrc). Small Capacity Models Wt-30 & Wt-50 Are Sleek, Compact And Instant Hot Water Generator Exclusively Designed For Hotels, Resorts, Dairies & Hospitals. Benefits Fully Automatic No Extra Man Power Is Required. Single Button Start / Stop With Automatic Controls. Easy To Operate. Economical Low Installation Cost. Minimum Space Required. No Water Treatment Required With Calorifier. High Operational Savings Of Over 50 % Against Electrical Heating. Low Maintenance Cost Front Door Access For Cleaning And Inspecting Flue Gas Port Without Removing The Burner. Exempted From Indian Boiler Regulation Act. Eco Friendly A Space Saver Smokeless Emission Less Floor Space Required Highly Compact Noise Less Operation Can Be Installed On Terrace, Basement Or Anywhere


Application : Hotels / Resorts Ashram / Dharmshala Dairy Garments / Laundry Swimming Pools Guar Gum Industry Electroplating Steel Plants
Request
Callback
Yes! I am Interested
X

Product Videos

Watch More Videos

Explore More Products

View All Products




Reach Us
Kinjal Shah
Thermotech Systems Limited
Plot No. 2607-2608, Phase IV, G. I. D. C., Vatva Industrial Estate
Ahmedabad - 382445, Gujarat, India
Get Directions


Call Us


Send E-mail